Losacero 3 ” (Steel Deck 3 ” , Losacero Sección 36/30)
Propiedades de la Sección
|
||||||
Calibre |
Espesor |
Peso |
Ix + |
Ix + |
Sx + |
Sx + |
24 |
0.0209 |
6.73 |
82.47 |
74.81 |
16.41 |
21.06 |
22 |
0.0295 |
8.31 |
100.70 |
98.54 |
22.16 |
23.17 |
20 |
0.0358 |
10.09 |
124.87 |
122.79 |
28.79 |
29.88 |
18
|
0.0474
|
13.35
|
165.33
|
165.18
|
41.30
|
42.88
|
Inercia Promedio de Sección Compuesta “lav” (cm4/m)
|
|||||
Calibre |
Espesor de Concreto |
||||
5 cm |
6 cm |
8 cm |
10 cm |
12 cm |
|
24 |
492.83 |
634.33 |
1008.64 |
1522.53 |
2197.28 |
22 |
545.26 |
697.84 |
1099.96 |
1649.37 |
2367.52 |
20
|
604.55 |
768.76 |
1200.30 |
1787.52 |
2552.09 |
18
|
702.31
|
886.06
|
1367.42
|
2019.26
|
2863.69
|
Módulo de Sección Inf. Seccion Compuesta “Sc” (cm3/m)
|
|||||
Calibre |
Espesor de Concreto |
||||
5 cm |
6 cm |
8 cm |
10 cm |
12 cm |
|
24 |
83.51 |
89.67 |
103.09 |
117.42 |
132.30 |
22 |
102.88 |
110.29 |
126.54 |
143.99 |
162.16 |
20
|
125.47 |
134.10 |
153.30 |
174.09 |
195.84 |
18
|
166.73
|
177.49
|
201.93
|
228.73
|
256.95
|
Losacero 3″ Claros Máximos sin apuntalamiento (m)
|
||||||
Calibre |
Apoyo |
Espesor de Concreto | ||||
5 cm |
6 cm |
8 cm |
10 cm |
12 cm | ||
24 |
Simple
Dos Claros Tres Claros |
1.945 |
1.87 |
1.74 |
1.66 |
1.58 |
22 |
Simple |
2.34 |
2.24 |
2.09 |
1.99 |
1.88 |
20
|
Simple |
2.73 |
2.62 |
2.43 |
2.31 |
2.19 |
18
|
Simple
Dos Claros Tres Claros |
3.36 |
3.22 |
2.99 |
2.84 |
2.68 |
1) Los claros anteriores fueron determinados de acuerdo a la especificacón de SDI (Steel Deck Institute) para peso de la lamina del concreto fresco y una carga de construccion distribuida de 98 kg/m2 ó puntual de 223 kg/m de ancho, al centro del claro, considerándose como limitantes un esfuerzo de trabajo de .6 Fy o una deflexión maxima de L/180 ó 1.9 cms.
2) Los valores que aparecen en la tabla superior, sólo serán validos si la lámina está correctamente “fijada” a las vigas de apoyo.
3) Los claros deberán consederarse a “ejes” es decir a centros de apoyos.
Losacero 3″ Volumen de concreto (m3/m2)
|
|||||
Espesor de concreto sobre la cresta |
5 cm
|
6 cm
|
8 cm
|
10 cm
|
12 cm
|
Volumen de concreto |
0.087 |
0.097 |
0.117 |
0.137 |
0.157 |
Armado por temperatura
|
|||
Espesor de concreto |
Especificacion de la maya | Ast. de la Sección Especificada(cm2/m) |
Ast.Minimo (cm2/m) |
5 y 6 cm |
6 x 6 – 6/6 6 x 6 – 4/4 6 x 6 – 3/3 |
1.23 |
0.91 |
Losacero 3″ Sobrecarga Admisible (kg/m2) |
|||||||||||||
Separación entre apoyos (m) |
|||||||||||||
Calibre |
Espesor |
1 |
1.2
|
1.4
|
1.6
|
1.8
|
2
|
2.2
|
2.4
|
2.6
|
2.8
|
3
|
3.2
|
24
|
5 |
2000 |
2000 |
2000 |
2000 |
2000 |
1928 |
1475 |
1131 |
864 |
651 |
480 |
340 |
6
|
2000 |
2000 |
2000 |
2000 |
2000 |
1989
|
1504 |
1134 |
847 |
619 |
435 |
284 |
|
8
|
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
1544 |
1119 |
789 |
527
|
315 |
142
|
|
10
|
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
1592 |
1109 |
732 |
434 |
|||
12
|
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
1557
|
1012
|
588
|
251
|
|||
22
|
5
|
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
1679 |
1606 |
1276 |
1014 |
803 |
630
|
6
|
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
1685 |
1648 |
1294 |
1014 |
788 |
602 |
|
8
|
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
1723 |
1317 |
995 |
736 |
523 |
|
10
|
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
1809 |
1348 |
981 |
686 |
444 |
|
12
|
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
1822
|
1302
|
890
|
557
|
285
|
|
20
|
5
|
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
1794 |
1392 |
1405 |
1148 |
937 |
6
|
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
1810 |
1774 |
1433 |
1158 |
933 |
|
8
|
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
1823 |
1871 |
1481 |
1167 |
909 |
|
10
|
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000
|
1984 |
1541 |
1184 |
892 |
|
12
|
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000
|
2000
|
1533
|
1131
|
802
|
|
18
|
5
|
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
1787 |
1445 |
1165 |
6
|
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
1803 |
1439 |
1141 |
|
8
|
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
1827 |
1912 |
1573 |
|
10
|
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
1868 |
2000
|
1653 |
|
12
|
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000
|
2000
|
1674
|
Losacero 3″ Sobrecarga Admisible (kg/m2) |
|||||||||||||
Separación entre apoyos (m) |
|||||||||||||
Calibre |
Espesor |
1.8 |
2
|
2.2
|
2.4
|
2.6
|
2.8
|
3
|
3.2
|
3.4
|
3.6
|
3.8
|
4
|
24
|
5 |
2000 |
1777 |
1441 |
1186 |
988 |
830 |
703 |
599 |
513 |
440 |
379 |
327 |
6
|
2000 |
1992 |
1616 |
1331 |
1108 |
932 |
789 |
673 |
576 |
495 |
427 |
368 |
|
8
|
2000 |
2000 |
1967 |
1620
|
1349 |
1135 |
962 |
820 |
703 |
604 |
521 |
450 |
|
10
|
2000 |
2000 |
2000 |
1916 |
1598 |
1345 |
1141 |
975 |
837 |
721 |
623 |
539 |
|
12
|
2000 |
2000 |
2000 |
2000
|
1839
|
1548
|
1314
|
1122
|
963
|
830
|
717
|
621
|
|
22
|
5
|
2000 |
2000 |
1778 |
1469 |
1229 |
1038 |
884 |
758 |
653 |
566 |
492 |
428 |
6
|
2000 |
2000 |
1999 |
1652 |
1381 |
1167 |
994 |
853 |
735 |
637 |
554 |
483 |
|
8
|
2000 |
2000 |
2000 |
1774 |
1687 |
1426 |
1215 |
1043 |
900 |
780 |
679 |
592 |
|
10
|
2000 |
2000 |
2000 |
1999 |
2000 |
1692 |
1444 |
1240 |
1072 |
930 |
811 |
709 |
|
12
|
2000 |
2000 |
2000 |
2000
|
2000 |
1951
|
1665
|
1430
|
1236
|
1037
|
935
|
818
|
|
20
|
5
|
2000 |
2000 |
2000 |
2000
|
1488
|
1261 |
1078
|
929 |
804 |
700 |
612 |
537 |
6
|
2000 |
2000 |
2000 |
2000
|
1677
|
1422 |
1216 |
1048 |
908 |
791 |
692 |
607 |
|
8
|
2000 |
2000 |
2000 |
2000
|
2000
|
1744 |
1492 |
1286 |
1115 |
972 |
851 |
747 |
|
10
|
2000 |
2000 |
2000 |
2000
|
2000
|
2000
|
1775 |
1531 |
1329 |
1160 |
1017 |
894 |
|
12
|
2000 |
2000 |
2000 |
2000
|
2000
|
2000
|
2000
|
1769
|
1536
|
1341
|
1175
|
1034
|
|
18
|
5
|
2000 |
2000 |
2000 |
2000 |
1934 |
1645 |
1412 |
1222 |
1064 |
932 |
820 |
724 |
6
|
2000 |
2000 |
2000 |
2000 |
1934 |
1864 |
1600 |
1385 |
1207 |
1057 |
930 |
822 |
|
8
|
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
1711 |
1492 |
1308 |
1152 |
1019 |
|
10
|
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
1784 |
1566 |
1380 |
1222 |
|
12
|
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
1816
|
1602
|
1419
|
1) Las propiedades de la sección como lámina sin concreto han sido calculadas de acuerdo a las especificaciones del AISI del 86 (American Iron and Steel Institute). Las propiedades de la Sección Compuesta fueron calculadas bajo los lineamientos del Steel Deck Institute SDI del 91
2) El Acero utilizado para la fabricación del perfil es Grado 37 (Fy= 37 Ksi= 2600 kg/cm2) SAE 1010 y está acorde al ASTM A-653 para Zintro.
3) Metálico Base: Zintro Capa G-60 (0.6 oz/pie2, 275 gr/m2) ASTM A-653.
4) La Sobrecarga Admisible mostrada ya considera el peso propio de la lámina y del concreto. La Sobrecarga Admisible es considerada uniformemente distribuida y es lo que se tiene disponible para colocar sobre la Losacero, no se requiere factorizar la solicitación de carga.
5) Para la selección del claro de apoyo, calibre y espesor de concreto adecuado es indispensable utilizar esta tabla en conjunto con la de “Claros Máximos sin Apuntalamiento”.
6) Los valores de esta tabla serán aplicables si la lámina Losacero es debidamente sujetada a la estructura de soporte en cada valle, mediante tornillos autoperforantes, clavo de disparo o soldadura, así como, se deberá tener restricción al giro en los bordes discontinuos de la losa utilizando fronteras metálicas permanentes o conectores.
7) Estos valores mostrados no son aplicables a losas con cargas vivas móviles como es el caso de estacionamientos de autos, en este caso se deberá de consultar al Departamento de Asesoría Técnica de Construcción para su análisis especifico.
8) Para determinar la resistencia como losa (Losacero) se siguieron los lineamientos del Steel Deck Institute del 91 (SDI) considerando L/360 como el limite de deflexión.
9) Disponible en longitudes desde 2.44 m hasta 12.00 m.
10) SAOSA proporciona la presente información como respaldo para la aplicación de sus productos por lo que no se le podrá hacer responsable del mal uso que se le pudiera dar; se recomienda la asesoría de un Ingeniero capacitado que verifique la aplicabilidad de la misma.
* Contamos con el equipo necesario para cubrir
sus necesidades en medidas especiales.